The STARTINET procedure file is used to start the network. This file
indicates which network daemons—e.g., FTP, TELNET, INTERD,
SNMPD—are loaded at reset. See Figure 6.9 for an example STARTINET
file. The example file shipped in revision 1.20 and later of the PCBridge
software (1771-PCB) includes the startup of the INTERD and SNMPD
daemons. You can modify this file to choose which daemons are started
for your system. A line started with an asterisk (*) is a comment line.
Important: If you want to use the INTERD daemon, you must have
Series A Revision E (1.30) or later of the coprocessor firmware.
Figure 6.9
List of STARTINET File
$ list startinet
load -d inetdb ;* load inet database from ram-drive
load -d interd ;* load interd from ram-drive
load -d skimp ;* load snmpd from ram-drive
setip 130.151.128.1 130.151.228.255 255.255.255.0 taro
load -d le0_147 ;* load lance/enet descriptor from ram-drive
load -d socket ;* load socket descriptor from ram-drive
mbinstall ;* load and start mbuf handler
routed<>>>/nil& ;* start up routed
* ispstart& ;* comment since routed is running we don’t need it
sleep 2 ;* wait a couple seconds until things calm down
telnetd <>>>/nil& ;* start daemon if we’d like to support telnet
ftpd <>>>/nil& ;* start daemon if we’d like to support ftp
interd <>>>/nil& ;* start daemon if we’d like to support interchange
snmpd <>>>/nil& ;* start daemon if we’d like to support snmp
chd /dd ;* go to top of ram-drv directory
$
Password File
You must have a password file when using Ethernet. See the Create a User
Startup File section in Chapter 3 to set up your password file.
Ethernet Hardware Address
If your network administrator requires the control-coprocessor Ethernet
hardware address, then at the
$
prompt, enter
lestat
/le0
. You get the
screen illustrated in Figure 6.10. The Ethernet address is shown on the
fourth line in the example.
Important: The lestat utility works only after the Ethernet port is
initialized by the startup procedure file.