API Library of Routines
Appendix B
BASIC Function Codes
B-142
Function Name
Function
Number
Description
TAG_DEFINE
60
Define symbolic TAG to memory
TAG_UNDEF
61
Undefine symbolic TAG of memory calling
process
TAG_GLOBAL_UNDEF
62
Undefine symbolic TAG of memory any
process
TAG_DEF_AVAIL
63
Determine TAG definitions available
TAG_LINK
64
Get TAG handle to symbolic TAG
TAG_READ_W
65
Read data from a symbolic TAG after a
TAG_WRITE_W
TAG_READ
66
Read data from a symbolic TAG
TAG_WRITE_W
67
Write data to a symbolic TAG and wait for a
TAG_READ_W
TAG_WRITE
68
Write data to a symbolic TAG
TAG_LOCK
69
Lock the TAG from concurrent access
TAG_UNLOCK
70
Unlock the locked TAG
CC_ERROR
100
Get pointer to canned" error message
CC_ERRSTR
101
Transfer error message to user buffer
CC_DISPLAY_STR
102
Display 4 ASCII characters
CC_GET_DISPLAY_STR
103
Get the currently displayed characters
CC_DISPLAY_HEX
104
Display binary value in hexadecimal
CC_DISPLAY_EHEX
105
Display binary value in hexadecimal
CC_DISPLAY_DEC
106
Display binary value in decimal
CC_PLC_SYNC
107
Synchronize module to PLC scan
CC_PLC_STATUS
108
Get current PLC status information
CC_STATUS
111
Get current coprocessor status information
CC_EXPANDED_STATUS
112
Get current expanded coprocessor status
information
CC_PLC_BTW
113
Request PLCĆ5 to perform blockĆtransfer
read with an I/O module
CC_PLC_BTR
114
Request PLCĆ5 to perform blockĆtransfer
write with an I/O module