beautypg.com

Rockwell Automation 1747-ASB Remote I/O Adapter User Manual

Page 53

background image

Publication 1747-UM006B-EN-P - June 2003

Addressing 3-17

The following table provides the specialty I/O module mapping used
when discrete mode is selected.

The 1747-ASB module can block transfer map a maximum of eight
words.

Max. Specialty I/O
Module Image Size

Addressing
Mode

Specialty I/O
Module Mapping

I/O Module
Examples

1 Word

2-slot

Discrete

1747-KE

1-slot

Discrete

1/2-slot

Discrete

2 Words

2-slot

Block transfer

1746-NIO4I,
-NIO4V

1-slot

Discrete

1/2-slot

Discrete

3 or 4 Words

2-slot

Block transfer

1746-NI4,
-NO4V,
-IMC110

1-slot

Block transfer

1/2-slot

Discrete

5 to 8 Words

2-slot

Block transfer

1746-BAS,
-NR4, -NT4,
-HSTP1
1747-DCM

1-slot

Block transfer

1/2-slot

Block transfer