Chapter 5
Programming Parameters
5-13
Table 5.A Cont.
PARM
717
718
719
720
721
722
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
780
840
841
842
843
844
900
901
902
903
904
905
UNITS
%
RPM
RPM
RPM
SEC
SEC
SEC
SEC
%
SEC
%
%
Rad/Sec
Rad/Sec
X.XX
NAME
Proc Tri Lo Lim
Proc Trim Hi Lim
Proce Trim Out K
Ovld Pend Level
Proc Trim Lo Sum
Proc Trim Hi Sum
ABS Overspeed
Ext Overtemp Dly
SCR Overtemp Dly
Stall Delay
AC Line Tol Dly
Field Fault Threshold
Fld Failure Dly
Tach Loss CEMF
Tach Loss Vel
Arm Bridge Type
K Discontinuous
KP Armature Loop
KI Armature Loop
KP Field Loop
KI Field Loop
K Arm Volts
K AC Volts
Cur Desired BW
Cur Max BW
Cur Damp Factor
Firmware Ver No.
SP Indirect 1
SP Indirect 2
SP Indirect 3
SP Indirect 4
SP Indirect 5
Trend Sign Val
Trend Sign Val
Trend Sign Val
Trend Sign Val
Trend Logic Val
Trend Logic Val
MIN
–32767
–32767
–16.0
0.0244
–6xB.S.
+6xB.S.
0
0.1
0.1
0
0
0
0.1
0
.2441
0
33
0
0
0
0
3000
2000
100
100
0.8
–32767
–32767
–32767
–32767
–32767
–32767
–32767
–32767
–32767
0
0
MAX
32767
32767
+16.0
260
0
+6xB.S.
B.S.
3276.7
3276.7
100
1.0
100
5.0
50.0
50.0
1
2048
32767
32767
32767
32767
25000
15000
1000
1000
3.0
32767
32767
32767
32767
32767
32767
32767
32767
32767
*
*
FUNCTION/CLASSIFICATION/PORT
Process Trim Control/Set-Up
Process Trim Control/Set-Up
Process Trim Control/Set-Up
Fault Detection/Set-Up
Process Trim Control/Setup
Process Trim Control/Set-Up
Process Trim Control/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Fault Detection/Set-Up
Auto Tuning Setup/Basic
Current PI Control/Autotune
Current PI Control/Autotune
Current PI Control/Autotune
Field PI Control/Set-Up
Field PI Control/Set-Up
Feedback Control/Basic
Feedback Control/Basic
AutoTuning Setup/Autotune
AutoTuning Setup/Autotune
AutoTuning Setup/Autotune
SP Control/Configuration
SP Control/Configuration
SP Control/Configuration
SP Control/Configuration
SP Control/Configuration
Trend Function
Trend Function
Trend Function
Trend Function
Trend Function
Trend Function
HEX
2D4H
2D5H
2D6H
2D7H
2D8H
2D8H
2D9H
2DCH
2DDH
2DEH
2DFH
2E0H
2E1H
2E2H
2E3H
2E4H
2E5H
2E6H
2E7H
2E8H
2E9H
2EAH
2EBH
2ECH
2EDH
2EEH
348H
349H
34AH
34BH
34CH
INIT
–4096
4096
1.000
115
–6xB.S.
+6xB.S.
B.S./10
1.0
1.0
10.0
0.1
30
1.0
10.01
2.002
1
1024
710
90
16384
168
12500
7225
500
500
1.0
X.XX
0
0
0
0
0
0
0
0
0
0
0
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
EE
* See Parameter Description