95
Appendix B
Table 41 - Instance 102 (Revision 2)➊
The following services are implemented for the Assembly Object.
Table 42 - Ethernet Object Common Services
Connection Manager Object — CLASS CODE 0x06
No class or instance attributes are supported.
The following common service are implemented for the Connection Manager
Object.
Byte Size
Contents
2 Bytes
Revision = 2
2 Bytes
ScanList I/O Size
2 Bytes
Data Link Update Interval (ms)
2 Bytes
Reserved
2 Bytes
Data Link 1 Node
2 Bytes
Data Link 1 Parameter
2 Bytes
Data Link 2 Node
2 Bytes
Data Link 2 Parameter
2 Bytes
Data Link 3 Node
2 Bytes
Data Link 3 Parameter
2 Bytes
Data Link 4 Node
2 Bytes
Data Link 4 Parameter
2 Bytes
Data Link 5 Node
2 Bytes
Data Link 5 Parameter
2 Bytes
Data Link 6 Node
2 Bytes
Data Link 6 Parameter
: : : :
: : : :
2 Bytes
Data Link 48 Node
2 Bytes
Data Link 48 Parameter
➊
Available with firmware v 2.00 and higher.
Service Code
Implemented for:
Service Name
Class Instance Consuming Instance Producing
0x0E
Yes
Yes
Yes
Get Attribute Single
0x10
No
Yes
No
Set Attribute Single