Rockwell Automation 193-DNENCATR EtherNet/IP Communications Auxiliary User Manual User Manual
Page 74

74
Rockwell Automation Publication 193-UM014B-EN-P December 2011
Chapter 9
Table 10 - Parameter 2 — SL Entry 1 Status
Table 11 - Parameter 3 — SL Entry 2 Status
Table 12 - Parameter 4 — SL Entry 3 Status
Description
Access Rule
Data Type
Units
Value
Min.
Max. Default
Provides the status of the
first scan list entry in the
DeviceNet scanner.
Get
WORD
—
0
2047
0
Bit
0
On Line
4
No Such Device
8
Device Went Idle
1
Connection Timeout
5
Fragment Error
9
Automatic Device
Replacement Error
2
Keying Mismatch
6
Slave Initialization Error
3
Wrong Data Size
7
I/O Data Overflow
10
Acknoledgement Timeout
Description
Access Rule
Data Type
Units
Value
Min.
Max. Default
Provides the status of the
second scan list entry in the
DeviceNet scanner.
Get
WORD
—
0
2047
0
Bit
0
On Line
4
No Such Device
8
Device Went Idle
1
Connection Timeout
5
Fragment Error
9
Automatic Device
Replacement Error
2
Keying Mismatch
6
Slave Initialization Error
3
Wrong Data Size
7
I/O Data Overflow
10
Acknoledgement Timeout
Description
Access Rule
Data Type
Units
Value
Min.
Max. Default
Provides the status of the
third scan list entry in the
DeviceNet scanner.
Get
WORD
—
0
2047
0
Bit
0
On Line
4
No Such Device
8
Device Went Idle
1
Connection Timeout
5
Fragment Error
9
Automatic Device
Replacement Error
2
Keying Mismatch
6
Slave Initialization Error
3
Wrong Data Size
7
I/O Data Overflow
10
Acknoledgement Timeout