Specifications, A-2 supplemental drive information – Rockwell Automation 22A PowerFlex 4 User Manual FRN 6.xx User Manual
Page 74
A-2
Supplemental Drive Information
Specifications
Drive Ratings
Catalog
Number
Output Ratings
Input Ratings
Branch Circuit Protection
kW (HP)
Amps
Voltage
Range
kVA Amps Fuses
140M Motor
Protectors
(2)
(3)
Contactors
Min. Enclosure
Volume
(4)
(in.
3
)
100 - 120V AC (±10%) – 1-Phase Input, 0 - 230V 3-Phase Output
22A-V1P5N104
0.2 (0.25) 1.5
90-126
0.75 6.0
10
140M-C2E-C10
100-C09
1655
22A-V2P3N104
0.4 (0.5)
2.3
90-126
1.15 9.0
15
140M-C2E-C16
100-C12
1655
22A-V4P5N104
0.75 (1.0) 4.5
90-126
2.25 18.0
30
140M-D8E-C20
100-C23
1655
22A-V6P0N104
1.1 (1.5)
6.0
90-126
3.0
24.0
40
140M-F8E-C32
100-C37
1655
200 - 240V AC (±10%) – 1-Phase
(1)
Input, 0 - 230V 3-Phase Output, NO BRAKE
22A-A1P4N103
0.2 (0.25) 1.4
180-265 0.7
3.2
6
140M-C2E-B40
100-C09
1655
22A-A2P1N103
0.4 (0.5)
2.1
180-265 1.05 5.3
10
140M-C2E-B63
100-C09
1655
22A-A3P6N103
0.75 (1.0) 3.6
180-265 1.8
9.2
15
140M-C2E-C16
100-C12
1655
22A-A6P8N103
1.5 (2.0)
6.8
180-265 3.4
14.2
25
140M-C2E-C16
100-C16
1655
22A-A9P6N103
2.2 (3.0)
9.6
180-265 4.8
19.6
30
140M-D8E-C25
100-C23
1655
200 - 240V AC (±10%) – 1-Phase
Input, 0 - 230V 3-Phase Output
22A-A1P5N104
0.2 (0.25) 1.5
180-265 0.75 5.0
10
140M-C2E-B63
100-C09
1655
22A-A2P3N104
0.4 (0.5)
2.3
180-265 1.15 6.0
10
140M-C2E-B63
100-C09
1655
22A-A4P5N104
0.75 (1.0) 4.5
180-265 2.25 10.0
15
140M-C2E-C16
100-C12
1655
22A-A8P0N104
1.5 (2.0)
8.0
180-265 4.0
18.0
30
140M-D8E-C20
100-C23
1655
200 - 240V AC (±10%) – 3-Phase Input, 0 - 230V 3-Phase Output
22A-B1P5N104
0.2 (0.25) 1.5
180-265 0.75 1.8
3
140M-C2E-B25
100-C09
1655
22A-B2P3N104
0.4 (0.5)
2.3
180-265 1.15 2.5
6
140M-C2E-B40
100-C09
1655
22A-B4P5N104
0.75 (1.0) 4.5
180-265 2.25 5.2
10
140M-C2E-C10
100-C09
1655
22A-B8P0N104
1.5 (2.0)
8.0
180-265 4.0
9.5
15
140M-C2E-C16
100-C12
1655
22A-B012N104
2.2 (3.0)
12.0
180-265 5.5
15.5
25
140M-C2E-C16
100-C16
1655
22A-B017N104
3.7 (5.0)
17.5
180-265 8.6
21.0
30
140M-F8E-C25
100-C23
1655
380 - 480V AC (±10%) – 3-Phase
Input, 0 - 460V 3-Phase Output
22A-D1P4N104 0.4 (0.5)
1.4
340-528 1.4
1.8
3
140M-C2E-B25
100-C09
1655
22A-D2P3N104 0.75 (1.0) 2.3
340-528 2.3
3.2
6
140M-C2E-B40
100-C09
1655
22A-D4P0N104 1.5 (2.0)
4.0
340-528 4.0
5.7
10
140M-C2E-B63
100-C09
1655
22A-D6P0N104 2.2 (3.0)
6.0
340-528 5.9
7.5
15
140M-C2E-C10
100-C09
1655
22A-D8P7N104 3.7 (5.0)
8.7
340-528 8.6
9.0
15
140M-C2E-C16
100-C16
1655
Input/Output Ratings
Approvals
Output Frequency: 0-240 Hz (Programmable)
Efficiency: 97.5% (Typical)
Digital Control Inputs (Input Current = 6mA)
Analog Control Inputs
SRC (Source) Mode:
18-24V = ON
0-6V = OFF
SNK (Sink) Mode:
0-6V = ON
18-24V = OFF
4-20mA Analog: 250 ohm input impedance
0-10V DC Analog: 100k ohm input impedance
External Pot: 1-10k ohms, 2 Watt minimum
Control Output (Programmable Output, form C relay)
Resistive Rating: 3.0A at 30V DC, 125V AC and 240V AC
Inductive Rating: 0.5A at 30V DC, 125V AC, and 240V AC
Recommended Fuses and Circuit Breakers
Fuse: UL Class J, CC, T or Type BS88; 600V (550V) or equivalent. Circuit Breakers: HMCP or Bulletin 140U or equivalent.
Protective Features
Motor Protection: I
2
t overload protection - 150% for 60 Secs, 200% for 3 Secs (Provides Class 10 protection)
Overcurrent: 200% hardware limit, 300% instantaneous fault
Over Voltage:
100-120V AC Input – Trip occurs at 405V DC bus voltage (equivalent to 150V AC incoming line)
200-240V AC Input – Trip occurs at 405V DC bus voltage (equivalent to 290V AC incoming line)
380-460V AC Input – Trip occurs at 810V DC bus voltage (equivalent to 575V AC incoming line)
Under Voltage:
100-120V AC Input – Trip occurs at 210V DC bus voltage (equivalent to 75V AC incoming line)
200-240V AC Input – Trip occurs at 210V DC bus voltage (equivalent to 150V AC incoming line)
380-480V AC Input – Trip occurs at 390V DC bus voltage (equivalent to 275V AC incoming line)
Control Ride Through: Minimum ride through is 0.5 Secs - typical value 2 Secs
Faultless Power Ride Through: 100 milliseconds
Dynamic Braking
Internal brake IGBT included with all ratings except No Brake versions. Refer to Appendix B of the PowerFlex 4 User Manual
on CD for ordering information.
(1)
200-240V AC - 1-Phase drives are also available with an integral EMC filter. Catalog suffix changes from N103 to N113
and N104 to N114.
(2)
The AIC ratings of the Bulletin 140M Motor Protector Circuit Breakers may vary. See
UL
®
UL508C
CSA 22.2
No. 14
C
US
EMC Directive 89/336/EEC, LV Dir. 73/23/EEC
LV: EN
50178
EMC:
EN
61800-3