SPECIFICATIONS
Inputs:
Voltage input:
Auto sensing 12/24 VDC
Reset input:
N/O, Dry
Rex input:
N/O, Dry
Trigger:
N/C or N/O, Dry
Monitoring Outputs:
Alarm Output:
1 Amp @ 30VDC SPDT, dry
Locked Output:
1 Amp @ 30VDC SPDT, dry
Mechanical Specifications:
Controller:
6.5" x 4.5" x 1.5"
(165 x 114 x 38mm)
1581DE:
8.75" x 2.125" x 1.25"
(222 x 54 x 32mm)
1571DE/1511DE:
11" x 2.75" x 1.562"
(279 x 69.9 x 39.7mm)
1575DE/1576DE:
8.7" x 2.5" x 1.6"
(221 x 63.5 x 41mm)
PUSH UNTIL ALARM
SOUNDS. DOOR CAN BE
OPENED IN 15 SECONDS.
Standard Exit
Device
No switch
No Power Transfer
TO FIRE COMMAND
CENTER
115 VAC
Door With Latch Assembly
Activation By Door Movement
Power Supply
PUSH UNTIL ALARM
SOUNDS. DOOR CAN BE
OPENED IN 15 SECONDS.
PUSH UNTIL ALARM
SOUNDS. DOOR CAN BE
OPENED IN 15 SECONDS.
TO FIRE COMMAND
CENTER
115 VAC
Door Without Latch Assembly
Activation By Sure Exit Push Bar
R
Power Supply
Power Transfer
Hinge or Loop
MSB550/PSB560
REX Bar
MODEL
101-DE
1581DEV
1571DEV
1511DEV
101-KDE
1575DEU
1576DEU
DEC-J
101-DE, DEC-J, SHD-J
DELAYED EGRESS CONTROLLER
101-DE
Wall mount controller with keypad control and reset, 180mA @ 12/24 VDC.
101-KDE Wall mount controller with both keypad and key switch control and reset (less cylinder).
MAGNETIC LOCK WITH INTEGRATED ACTIVATION SENSOR
Specify 2 for pair of doors.
1511DEV Single, 1650 lbs. holding force, 670/350 mA @ 12/24 VDC, 628 std
1571DEV Single, 1200 lbs. holding force Energey Saver, 250/125 mA @ 12/24 VDC, 628 std
1581DEV Single, 650 lbs. holding force, 440/220 mA @ 12/24 VDC, 628 std
Outdoor Locks.
1575DEU Single outdoor magnetic lock with bond sensor, 630
1576DEU Single face drilled outdoor magnetic lock with bond sensor, 630
Lock Finish
Not available with outdoor lock
V 628 Clear Anodized Aluminum (Std) X Dark Bronze Power Coat (313/613 equal)
Y Black Anodized
Optional Outputs
B
Magnetic Bond sensor, indicates locked with full holding force, low holding force,
unlocked, tampering and obstructions (1581DEV SPST only).
D Door position sensor, indicates door open and door closed. Commonly used to
verify egress after alarm and exit delay activation. Not available with 1581DE,
1576DE or 1575DE.
VI
Spanish, or English and Spanish, or English and French verbal announcement.
VIC Custom verbal announcement (minimum 10 piece purchase).
Accessories
MSB550
Mechanical REX Exit bar for activation of locks on doors without latch assemblies.
PSB560
Sure Exit REX sensor bar for activation of locks on doors without latch assemblies
101-4AM
Four door station with LED’s and alarm tone for remote annunciation (indoor use).
TCC
Desk top console for remote control and annunciation of 4 – 12 doors.
101-1AK
Outdoor reset/bypass key switch with LED and Audible annunciator. 2-gang outdoor
box required. (Interior 101-DE and 1575DE or 1576DE outdoor magnetic lock required).
(Cylinder not included).
DEC-J
3-gang Interior surface mount box for 101-DE
1, 2 or 3 gang box mounted.
SHD-J
Shroud for surface mount box DEC-J outdoor use
DEC-J required.
R
Only 101DE/KDE have been UL Listed as
Special Locking Arrangements to UL
standard 294 and NFPA 101.