SDC 101-DE/101-KDE Delayed Egress Controller User Manual

Features, Code compliance, Application

background image

INSTALLATION INSTRUCTIONS

101-DE/101-KDE

Features:

Egress Delay

15 or 30 second exit delay
1 or 2 second nuisance delay

Built-In 3 Function keypad

Alarm and lock reset
1 to 30 second bypass
Sustained bypass
Additional keyswitch optional

Control Inputs

1 to 30 second request-to-exit and bypass
input with anti-tailgate and jumper
selectable door prop alarm.
Reset

Built-In Annunciation

Armed mode
Nuisance mode
Irreversible egress mode
Release mode
Digital countdown mode
Field selectable voice notification or tone
Field selectable male voice with security
message or female voice with safety
message

Monitoring Outputs

Armed mode
Egress initiation status
Released status

Optional EMLock Outputs

Door position sensor – indicates door
open and door closed, commonly used to
verify egress after release.
Magnetic bond sensor – indicates locked
with full holding force, low holding force,
unlocked and tampering.

Triggering Options

Egress alarm triggered by door
movement when used with SDC
1500DE series EMLocks.
Trigger input from external device
field selectable (N/O or N/C)

Field selectable automatic or manual
power up after emergency release or
power loss. Use of manual power up
complies with California Building Code
(OSHPD) requirements.

Code Compliance

IFC International fire Code
IBC International Building Code
NFPA 101 Life Safety Code
NFPA 1 Uniform Fire Code
California Building Code

P:\INSTALLATION INST\Delayed Egress\INST-101DE_KDE.vsd Rev B10 04-13 Page 1

Any suggestions or comments to this instruction or

product are welcome. Please contact us through

our website or email [email protected]

Application:

When unauthorized egress is initiated SDC

Exit Check

®

delays egress

through the door for 15 seconds (or 30 seconds). Meanwhile, the person
exiting must wait while personnel or security responds. The door unlocks
after 15 seconds have elapsed permitting egress. When powered by a fire
control supervised power supply, the lock will release immediately in an
emergency. The digital keypad eliminates the need to carry and locate
keys for reset and bypass functions.

Choice of Mounting

Recessed mounted

(3 gang metal plaster ring included)

Surface mounted with optional 3 gang
box (DEC-J)
Optional shroud (SHD-J) to be used with
DEC-J surface box.

Exit Check

®

applications include:

Restricting the egress of wandering patients for their own safety.
Restricting the egress of commercial center patrons for security application needs.
Controlling pedestrian traffic in transportation facilities, including airport jetways
and tarmacs
Reducing Shoplifting and Employee Theft

Display Modes

Door armed and locked.

Alarm countdown has ended,
door is unlocked and alarm sounding
until reset.

Door unlocked and alarm is shunted
(REX or Bypass)

Door has been opened after REX,
Bypass or Alarm.

15

00

- -

- -

- -

- -

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: [email protected]

Verbal Exit Instructions or
Alarm Tone Only and
Digital Countdown Display