SDC 921P EntryCheck User Manual
Page 7
Beep Sounds During Auxiliary Relay
Default: No
Selects whether or not the keypad beeps during Auxiliary Relay
activation.
Press: 42 # Sound #
Sound=1 for Yes, =0 for No
Beep Sounds During Output #3
Default: No
Selects whether or not the keypad beeps during Output #3
activation.
Press: 43 # Sound #
Sound=1 for Yes, =0 for No
Beep Sounds During Output #4
Default: No
Selects whether or not the keypad beeps during Output #4
activation.
Press: 44 # Sound #
Sound=1 for Yes, =0 for No
Keypad Lockout Count
Default: 3 Attempts
Sets the number or incorrect entry code attempts allowed
before the keypad “locks out” for 60 seconds.
Press: 50 # Attempts #
Attempts=Number of attempts before lockout (2-7)
* Refer to Option 13 to Enable Lockout Feature
Anti-Pass Back Time
Default: No Anti-Pass Back
Sets the length of time an entry code will not function after it is
used.
Press: 51 # Minutes #
Minutes=Time in minutes (2-4), 0=No Anti-passback
Beep Sounds During Main Relay
Default: No
Selects whether or not the keypad beeps during Main Relay
activation.
Press: 41 # Sound #
Sound=1 for Yes, =0 for No
Solid-state Output #4 On-time
Default: 02 Seconds
Sets the length of time Output #4 activates when triggered.
Press: 24 # Seconds #
Seconds=Output time in seconds (0-60), 99=Toggle Mode
Beep Sounds on Keystrokes
Default: Yes
Selects whether or not the keypad beeps as each key is pressed.
Press: 40 # Sound #
Sound=1 for Yes, =0 for No
Selects mode for Keypad LED Backlight
Default: 30 Seconds
Selects whether or not the keypad back light stays OFF, lights for 30
seconds when activated or stays ON.
Press: 52 # Output #
0 = Light always OFF
1 = 30 sec light when activated (default)
2 = Light always ON
Solid-state Output #3 On-time
Default: 02 Seconds
Sets the length of time Output #3 activates when triggered.
Press: 23 # Seconds #
Seconds=Output time in seconds (0-60), 99=Toggle Mode
Beep Sounds Anti-Tamper Activation
Default: No
Selects whether or not the keypad beeps during Anti-Tamper
switch activation.
Press: 45 # Sound #
Sound=1 for Yes, =0 for No
Changing the Beeper Sound Level
The Keypad’s beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.
Changing the 6-Digit Master Programming Code
Press: 98 # Master Code # Master Code #
Master Code=The new 6-digit Master Programming Code
P:\INSTALLATION INST\Access Controls\INST-921\INST-921P.vsd Rev C 04-14 Page 7
RESETTING KEYPAD
Master Reset
CAUTION: Performing a master reset will clear the
entire memory of the 921P and return all programmable
options to the factory default values. ALL ENTRY
CODES WILL BE ERASED. NOTE: The Master Code will
NOT be reset.
STEP 1 Disconnect power from the 921P controller.
STEP 2 Press and hold down the * and # keys on the keypad.
STEP 3 Reconnect the controller power, continue holding the
keys down until the red indicator starts flashing.
STEP 4 Release the keys. The red and yellow indicators will
remain lit until the process is complete, then the
yellow indicator will go out.
Resetting the Master Code
STEP 1 Remove the cover from the 921P controller box and
disconnect power.
STEP 2 Locate & Remove jumper at JP2. Reference page 3.
STEP 3 Re-apply power. You will get a single beep and
the yellow LED on the keypad will flash momentarily.
STEP 4 Replace jumper on JP2.
THE MASTER PROGRAMMING CODE IS NOW 123456.
Door Ajar Timer
Default: 60 Seconds
Sets the amount of time the door may be held open after an
authorized access. The DOOR AJAR output will activate after the
time expires.
Press: 25 # Seconds #
Seconds=Held open time in seconds (1-60)