beautypg.com

Caution – SDC 920P EntryCheck User Manual

Page 2

background image

P:\INSTALLATION INST\Access Controls\INST-920\INST-920P.vsd Rev D 03-14 Page 2

Test your new user

Present your card or enter an authorized PIN code + #. The green indicator should

illuminate and the main relay should activate, unlocking the door for 5 seconds.

CAUTION

IF THE UNIT IS AC POWERED, MAKE SURE

THAT THE SECONDARY OF THE SYSTEM IS

ISOLATED FROM EARTH GROUND

!

!

RED/GREEN
POWER/ACCESS/ERROR
INDICATOR

YELLOW
“PROGRAM”
INDICATOR

KEYPAD

FRONT

PROX

Antenna

Fig. 2 Wiring Pigtail Color Code

KEYPAD
POWER

WIRE
HARNESS
(E1-E8)

MAIN
RELAY

AUXILIARY
RELAY

ANTI-TAMPER
SWITCH

BACK

JP1

E1

E8

JP2

TO POWER SUPPLY

KEY PAD POWER

12-24 VOLTS

AC OR DC

}

+

-

RED

BLACK

NC

AUXILIARY RELAY

2 AMPS @ 28VDC MAX

}

NO

COM

ORG/BLK

BLK/WHT

BRN/YEL

FAIL SECURE CONNECTION

FAIL SAFE CONNECTION

MAIN RELAY

5 AMPS @ 28VDC MAX

}

NO

COM

NC

ORANGE

WHITE

YELLOW

Set default parameters (first time use)

Step 1. Enter: #9# 123456#

Enter programming mode (default master code=123456)

Step 2. Enter: 03# 4#

Set the entry code length to 4 digits

Step 3. Enter: 21# 5#

Set the main relay activation time for 5 sec.

Step 4. Enter:

#

Exit programming mode

**

**

Assign a user (Card only)

Step 1. Enter: #9# 123456#

Enter programming mode (default master code)

Step 2. Enter: 06# 002# 9876# 9876# 1# (Present card)

Assign card to User 002 with a

PIN code of ‘9876’. Activate
the main relay when validated.

Step 3. Repeat Step 2 to enter another unique user & card, or continue to Step 4.

Step 4. Enter:

#

Exit programming mode.

Assign a user (PIN only)

Step 1. Enter: #9# 123456#

Enter programming mode (default master code)

Step 2. Enter: 01# 003# 2580# 2580# 1# Assign User 003 with a PIN code of ‘2580’.

Activate the main relay when entered.

Step 3. Repeat Step 2 to enter another unique user & PIN or continue to Step 4.

Step 4. Enter:

#

Exit programming mode

**

Deleting a user code

Step 1. Enter: #9# 123456#

Enter programming mode (default master code)

Step 2. Enter: 02# 002# 002#

User 002 has been deleted.

Step 3. Enter:

#

Exit programming mode

**

BLACK

PINK/SALMON

GREEN

GRAY

BLACK

VIOLET

BLACK

BLUE

DOOR POSITION

SWITCH

[N/C]

REQUEST-TO-EXIT

SWITCH

[N/O]

GROUND

OUTPUT #4

OUTPUT #3

GROUND

GROUND

SENSE

REQUEST TO EXIT

GROUND

EARTH

GROUND

CONNECTION

E

1

E

8

E

7

E

6

E

5

E

4

E

3

E

2

C

NO

C

NC

NO

AUXILIARY OUTPUTS

100mA MAX TO COMMON

{

*

*

QuickStart Programming

You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the 920P
EntryCheck™ is in programming mode. Use the option codes to program each function. After the new data entry is complete for
each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the
programming has been accepted. The red indicator will light if any programming data is entered incorrectly or the function is
rejected. If a red indicator is seen, the entire function (option code + data) will have to be fully re-entered. The keypad will remain
in programming mode until # is pressed or after 30 seconds of inactivity.

**