T-armor, Drop valley - fixed – Metal Sales T-Armor Series User Manual
Page 72
© Metal Sales Manufacturing Corporation / Subject to change without notice 09/14
T-ARMOR
72
DROP VALLEY - FIXED
INSTALLATION NOTES
#14-13 Deck Screws (1'-0" oc)
Clips w/ (2) #14-13 Deck Screws
Drop Valley
Tube Sealant (Between Panel Ribs)
Eave Plate
Double Bead Tape Sealant
Wood Blocking (by others)
T-Armor Panel
Bearing Plate
3:12 Slope
Minimum
All Eave and Drop Valley flashings must be installed prior
to panel installation.
1. Install new Eave Plate over top of rigid board insulation
and fasten through the Valley Plate and wood blocking
into the metal deck at 1'-0" oc.
2. Install new Drop Valley flashing on top of the Eave Plate.
3. If two or more flashings are required, lap the flashing
over the previously installed flashing by a minimum of
6", placing two beads of Tube Sealant between the
flashings. Locate beads of Tube Sealant so that it does
not press out of the lap. Do not install fasteners through
the Drop Valley lap.
4. Apply a continuous row of Double Bead Tape Sealant across the top of each side of the Drop Valley flashing.
5. Set panel into place and use #12-14
x1
1
/
4
"
Self Driller XL screws to attach (see page 52).
6. Apply Tube Sealant up the side and across the top of the panel ribs before installing the next panel.
Moisture Barrier (by others)
Metal Decking
(by others)
#12-14x1
1
/
4
" SD XL (See Pg 52)
Additional #14-13 Deck
Screws may be required for
areas with large snow loads
*Panel cap not shown for clarity
9" max