T-armor, Post hung gutter - fixed – Metal Sales T-Armor Series User Manual
Page 69
© Metal Sales Manufacturing Corporation / Subject to change without notice 09/14
69
T-ARMOR
CAUTION
In locations where heavy rainfall or severe ice and
snow may occur, Metal Sales' standard gutters may
not be suitable for use.
INSTALLATION NOTES
All Eave flashings must be installed prior to panel
installation.
1. Install new Eave Plate over top of rigid board insulation
and fasten through the wood blocking into the metal deck
with #14-13 Deck Screws at 1'-0" oc.
2. Install new Eave flashing on top of the Eave Plate.
3. Apply a continuous row of Double Bead Tape Sealant
across the top of the Eave flashing.
4. Set panel into place and use #12-14
x1
1
/
4
"
Self Driller XL
screws to fasten into place (see page 52).
5. Apply Tube Sealant up the side and across the top of the
panel ribs before installing the next panel.
6. Install the Gutter by sliding it behind the Eave. Install the
Post Hung Gutter Hangers at 2'-0" oc, fastening through
the Eave into the roof framing.
7. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of
2", place two beads of Tube Sealant between the flashings and secure with Pop Rivets, 2.5" oc.
POST HUNG GUTTER - FIXED
Eave
Eave Plate
T-Armor Panel
Bearing Plate
Clip w/ (2) #14-13 Deck Screws
#14-13 Deck Screw (1'-0" oc)
#12-14x1
1
/
4
" SD XL (See Pg 52)
#10-14x1
1
/
2
" Wood Screw XL (1 per hanger)
Double Bead Tape Sealant
Tube Sealant (between panel ribs)
Moisture Barrier (By others)
1
/
8
"x
3
/
16
" Pop Rivet (1 per Hanger)
Post Hung Gutter
Post Hung Gutter Hanger (2'-0" oc)
1
/
2
:12 Slope
Minimum
Wood Blocking
Metal Decking (By others)
Additional #14-13 Deck
Screws may be required for
areas with large snow loads
*Panel cap not shown for clarity
9" max