T-armor, Rakewall – Metal Sales T-Armor Series User Manual
Page 64

© Metal Sales Manufacturing Corporation / Subject to change without notice 09/14
T-ARMOR
64
INSTALLATION NOTES
RAKEWALL
Floating Rake Angle and T-Armor panels must be installed
prior to Rakewall flashing installation (See pages 47-56).
1. With T-Armor panel properly nested beside Offset Rake
Slide, apply a row of Double Bead Tape Sealant across
upper side of Offset Rake Slide.
2. Fasten through Offset Rake Slide, Tape Sealant, panel
and into Floating Rake Angle with #12-14 x 1
1
/
4
" Self
Driller XL screws, 1'-0" oc.
3. Apply row of Double Bead Tape Sealant on top of Offset
Rake Slide.
4. Install Rakewall so that top of flashing is flush with top
of Offset Rake Slide and panel rib. Fasten through
Rakewall, Tape Sealant and into Offset Rake Slide with
¼"-14 x
7
/
8
" Stitch XL screws, 1'-0" oc.
5. Install Counter Flashing, Reglet or wall panel and fasten
to parapet wall with appropriate fastener, 1'-0" oc. If Counter Flashing or Reglet is used, seal to wall with
Tube Sealant. Do NOT fasten Rakewall to parapet wall.
6. If two or more flashings are required, lap the upslope flashing over the previously installed flashing by a
minimum of 2" placing a bead of Tube Sealant between the flashings and secure with Pop Rivets, 2.5" oc.
Moisture Barrier (by others)
1
/
4
"-14 x
7
/
8
" Stitch XL (1'-0" oc)
Rakewall
Starter
Double Bead Tape Sealant
T-Armor Panel
Offset Rake Slide
Floating Rake Zee
Tube Sealant
#12-14 x 1
1
/
4
" SD XL (1'-0" oc)
#14-13 Deck Screw (1'-0" oc)**
Fastener (by others)
Counter Flashing
CAUTION
**NOTE: DO NOT OVER TIGHTEN.
Fastener must be loose enough to allow for
Rake Angle to move back and forth
Metal Decking (By others)
With Reglet
With Counter