C13066 | 0x1f8d prespayloadlimit rpdo cn, C13067 | 0x1f8d prespayloadlimit rpdo, C13071 | 0x1f98.4 preqpayloadlimit rpdo – Lenze E84AYCEC User Manual
Page 72: E84aycec communication manual (ethernet powerlink)

E84AYCEC communication manual (Ethernet POWERLINK)
Parameter reference
Parameters of the communication module
72
L
EDS84AYCEC EN 3.0 - 09/2012
C13066
C13067
C13071
Parameter | Name:
C13066 | 0x1F8D PResPayloadLimit RPDO CN
Data type: UNSIGNED_16
Index: 11509
d
= 2CF5
h
The code defines the reserved user data length of the PRes telegrams for controlled nodes 1 ... 100. Each subcode
number corresponds to one EPL node with the same node ID. The EPL node must be enabled via code
.
The subcodes describe the PRes telegrams received. The value must be within the range of 36 ... 1490 bytes.
The values are upper limit values for the entire size of the PDO mappings for received PRes telegrams.
In the configured state, the values stored for the EPL nodes must be identical to the corresponding
entries.
C13066 must have an identical value in all EPL nodes of the network.
Setting range
(min. value | unit | max. value)
0
byte
1490
Subcodes
Lenze setting
Info
C13066/1
0 byte
...
...
C13066/100
0 byte
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13067 | 0x1F8D PResPayloadLimit RPDO
Data type: UNSIGNED_16
Index: 11508
d
= 2CF4
h
The code defines the reserved user data length of the PRes frames for managing node, diagnostic device or router.
Each subcode number corresponds to one EPL node with the same node ID. The EPL node must be enabled via code
The subcode describes the PRes telegrams received. The value must be within the limits of 36 ... 1490 bytes.
The values are upper limit values for the entire size of the PDO mappings for received PRes telegrams.
In the configured state, the values stored for the nodes must be identical to the corresponding
entries.
C13067 must have an identical value in all EPL nodes of the network.
Setting range
(min. value | unit | max. value)
0
byte
1490
Subcodes
Lenze setting
Info
C13067/1
0 byte
Managing node
C13067/2
0 byte
Diagnostics device
C13067/3
0 byte
Router
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13071 | 0x1F98.4 PReqPayloadLimit RPDO
Data type: UNSIGNED_16
Index: 11504
d
= 2CF0
h
The code defines the maximum data size to be received by the controlled node via PReq for the current network
configuration. C13071 is an upper limit value for the entire size of the PDO mapping for the PReq telegram.
In the configured state, the value must be identical to the entry for a response valid for the EPL node.
Setting range
(min. value | unit | max. value)
Lenze setting
36
byte
1490 36 bytes
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT