10 error messages, Error messages, E84aycec communication manual (ethernet powerlink) – Lenze E84AYCEC User Manual
Page 62

E84AYCEC communication manual (Ethernet POWERLINK)
Error messages
Short overview of the Ethernet POWERLINK error messages
62
L
EDS84AYCEC EN 3.0 - 09/2012
10
Error messages
This chapter supplements the error list in the software manual and the »Engineer« online
help for the Inverter Drive 8400 by the error messages of the communication module.
10.1
Short overview of the Ethernet POWERLINK error messages
The following table contains all error messages of the communication module in
numerical order of the error numbers. Moreover the preset error response and - if
applicable - the parameters for setting the error response are specified.
Tip!
When you click the cross-reference in the first column, you will get to the detailed
description (causes and remedies) of the corresponding error message.
Software manual/»Engineer« online help for the Inverter Drive 8400
Here you will find general information on diagnostics & fault analysis and error
messages.
Error no.
[hex]
Subject area
no.
[dec]
Error no.
[dec]
Error text
Error type
(Error response)
adjustable in
444
12544
EPL: Lost connection to 8400 target
1: Error
-
444
21809
EPL: NV memory: No access
1: Error
-
444
21810
EPL: NV memory: Read error
1: Error
-
444
21811
EPL: NV memory: Write error
1: Error
-
444
24592
EPL: Restart after watchdog reset
1: Error
-
444
24593
EPL: Watchdog reset
1: Error
-
444
24832
EPL: Software error
1: Error
-
444
24833
EPL: Fatal software error
1: Error
-
444
24848
EPL: Invalid PDO mapping
1: Error
-
444
25631
EPL: Invalid parameter set
1: Error
-
444
25632
EPL: Default setting loaded
1: Error
-
444
25648
EPL: Invalid module configuration
1: Error
-
444
33073
EPL: OPERATIONAL status left
1: Error
444
33377
EPL: Invalid address selected
1: Error
-
444
33381
EPL: Synchronisation of MN lost
0: None
444
33382
EPL: Frame error (CRC)
0: None