5 ethernet powerlink connection, Ethernet powerlink connection, Ethernet powerlink connection ( 31) – Lenze E84AYCEC User Manual
Page 31: E84aycec communication manual (ethernet powerlink)
EDS84AYCEC EN 3.0 - 09/2012
L
31
E84AYCEC communication manual (Ethernet POWERLINK)
Installation
Electrical installation
5.2.5
Ethernet POWERLINK connection
Ethernet POWERLINK is connected via the RJ45 sockets X251 (P1) and X252 (P2).
[5-6]
Ethernet POWERLINK connections X251 (P1) and X252 (P2)
If possible, do not wire more than 10 nodes in a row in a network line.
In case of more than 10 nodes you should deactivate the automatic calculation of the
hub level in the »Engineer« and enter it manually to increase the performance.
With a cycle time of 1 ms, 25 nodes can be operated.
– The number of nodes can be increased if the EPL cycle time is increased as well.
You can use a standard Ethernet patch cable to connect the communication module to
the Ethernet POWERLINK fieldbus (see
).
The installation and removal of the Ethernet cables is optimised for use of connectors
according to the "Automation Initiative of German Domestic Automobile
Manufacturers" (AIDA).
E84YCEC001E
Note!
To prevent the RJ45 socket from being damaged, hold the Ethernet cable
connector straight (at a right angle) when inserting it into or removing it from
the socket.