beautypg.com

Set station configuration, Function selector switch, Station installation – ETC Echo Inspire Station User Manual

Page 3: Page 3 of 8 inspire station installation guide, Front of station rear of station

background image

E T C I n s t a l l a t i o n G u i d e

Station Installation

Page 3 of 8

Inspire Station Installation Guide

b: Use one WAGO connector, provided in the termination kit, to connect

the power pigtail and the installed control wires.

Open the terminal

levers on the WAGO connector and insert the installed (typically
black) Belden 8471 wire and the black lead from the power pigtail
into the terminals. Then close the levers.

c: Repeat for the installed (typically white) Belden 8471 power wires and

the remaining white wire from the power pigtail using a new WAGO
connector.

d: Install the two pin connector from the power pigtail to the mating

receptacle on the station electronics.

Set Station Configuration

Inspire stations have on-board switch and mode button settings that determine
functionality, space assignment, and station address.

Function Selector Switch

Sets the station functionality to PRESET, CUSTOM, or ZONE. The Program
Mode
switch setting also affects the function of this Function Switch.

PRESET - When set, all buttons on the station will perform preset
related actions. Preset functionality is the default.

CUSTOM - This function is reserved for future development.

ZONE- When set, all buttons on the station will perform zone related
actions; allowing manual adjustment of zone levels to record (snapshot)
presets for later recall.

24VDC, @5mA

For use with Unison Echo and

Sensor3 Control Systems Only.

Type 1

LISTED

IND. CONTROL EQUIP

9Z49

ENERGY MGMT. EQUIP

Switches

1 - Use Off

2 - Amber LED Disable

8 - Restore Defaults

RECORD/

PROGRAM

MODE

Function switch

PRESET

CUSTOM

ZONE

front of

station

rear of

station