Protocol 3 Controller

Owner’s Manual

50

Version 1.2

Copyright © 2013 by Despatch Industries.

All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.

Alarm Selection

Parameter 1

Parameter 2

Parameter 3

Process Low

Alarm Value
(Degrees)

Alarm Hysteresis (Degrees)

Alarm Inhibit

PV-SP Deviation

Alarm Value
(Degrees)

Alarm Hysteresis (Degrees)

Alarm Inhibit

Band

Alarm Value
(Degrees)

Alarm Hysteresis (Degrees)

Alarm Inhibit

Signal Change Per
Min

Alarm Value
(Degrees)

Minimum Duration
(Seconds)

Alarm Inhibit

Input Signal Break

N/A

N/A

N/A

Control Loop

Loop Alarm
Type

Manual Loop Alarm Time
(mm:ss) (active only if loop
alarm type is manual)

N/A

% Memory Used

Alarm Value (%) Alarm Inhibit

N/A


5.6.1.3. Using Alarms to Switch Relay Outputs

The Protocol 3 controller allows alarm states to trigger any of the five relay outputs on the
controller. Each output can be set to a specific alarm or multiple alarms using the

Or Alarms

and

Alarm and Events

functions. To configure an alarm state to trigger a relay output:

1. From

Configuration Menu

, use

and

to scroll to and highlight

Output

Configuration

then press

to access the

Output Configuration

Menu

.

2. Press

to move forward through the different parameters in the menu,

and

to enter the setting for a parameter,

to move back through the different parameters.

3. Press

and

together (simultaneously) to return to the

Configuration Menu

.