Table 6. Data Recorder.
Item
Description
Recording Memory:
1Mb non
‐volatile flash memory. Data retained when power is
turned off
Recording Interval:
1; 2; 5; 10; 15; 30 seconds or 1; 2; 5; 10; 15; 30 minutes
Recording Capacity:
Dependent on sample rate and number of values recorded.
Two values can be recorded for up to 7 days at 10s intervals.
More values or faster sample rates deduce the maximum
duration.
RTC Battery Type:
VARTA CR 1616 3V Lithium. Clock runs for >1 year without
power (Part # 274030)
RTC accuracy:
Real Time Clock error <1 second per day