beautypg.com

Assembly & setup, Install the protocol 3 controller, Protocol 3 controller conversion with no options – Despatch Protocol 3 Controller User Manual

Page 18: Danger, Warning

background image

A

SSEMBLY

&

S

ETUP

Protocol 3 Controller

Owner’s Manual

18

Version 1.2

Copyright © 2013 by Despatch Industries.

All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.

4.

Assembly & Setup

Danger!

All grounding and safety equipment must be in compliance with
applicable codes, ordinances and accepted safe practices.

4.1. Install the Protocol 3 Controller

When replacing a Protocol 3 controller, follow the steps below. Tools required for installation
include ¼” socket set with #1 bit, #2 Philips screwdriver.
1.

Disconnect the power.

2.

Unplug all terminals on the rear of the control, noting the proper connections (Figure 3).

3.

Remove the retaining clips for the controller.

4.

Remove the controller.

5.

Insert the new controller into the panel.

6.

Fasten the retaining clips.

7.

Re-plug all terminals.

8.

Secure the control panel.


4.2. Protocol 3 Controller Conversion with NO Options

To replace the older model Protocol Plus controller with the newer Protocol 3 controller, connect
terminal blocks as indicated in Table 7 and Figure 3.

Table 7. Protocol Plus to Protocol 3 Controller Conversion.

Terminal Block

Former

Protocol Plus Connections

New

Protocol 3 Connections

Three pin terminal block for
power leads

Terminals 30, 31, 32

Terminals 1, 2, 3

Five pin terminal block for
SSR and Hi-limit

Terminals 17, 18, 19, 20, 21

Terminals 26, 27, 28, 29, 30

Remove the four-pin terminal
block from thermocouples and
rewire with two three-pin
blocks.

Control Thermocouple

Terminals 13, 14

Control Thermocouple

Terminals 17, 18

Hi-limit Thermocouple

Terminals 15, 16

Hi-limit Thermocouple

Terminals 32, 33

Warning!


Disconnect the main power switch or power cord before
attempting any repair or adjustment.