Table 12. Profile Setup Steps, Options and Descriptions.
Step # Protocol 3 Descriptor
Option
Description
General Configuration
1.
Remote Profile Control
Disabled
Disallow a remote source to run a profile
Enabled
Allow a remote source to run a profile
2.
Automatic Start
Disabled
Disallow use of delayed start time
Enabled
Allow controller to start at a later time with
programmed delay
Create a Profile
3.
Enter a Profile Name
Unique name for each profile using up to 8
characters
4.
Profile Start Trigger
None
Profile start not delayed
After Delay
Set hours and minutes to delay before
starting the profile
Day and Time
Set time of day (hour and minutes) and day
of week to start profile. Options include
each day of the week and combinations of
days.
5.
Profile Recovery
Method
If power-down occurs while this profile is
running, specify the action for the controller
to take during power-up:
Control Off
Controller goes to OFF
Restart Profile
Controller restarts current profile
Maintain Last
Profile SP
Controller maintains previous profile
setpoint
Continue
Profile
Controller continues (for specified time) the
profile from where it was when power
failed.
Profile Abort Action
If program aborts, profile should:
Control Off
Controller goes off
6.
Maintain Last
Profile SP
Choose the number of times to cycle the
program, up to an infinite number of times.
Edit a Profile Segment
7.
Edit Segment Number
Ramp Time
Set target setpoint (degrees centigrade)
Set the segment ramp time (hh:mm:ss)
Set the Auto-Hold Type: None, Above
Setpoint, Below Setpoint, Band.
Set Events 1-5: Press
or
to
toggle between Active and Inactive.
8.
Ramp Rate
Set the target setpoint (degrees
centigrade)
Set the segment ramp rate in units per
hour
Set the Auto-Hold Type: None, Above
Setpoint, Below Setpoint, Band.
Set Events 1-5: Press
or
to
toggle between Active and Inactive.
9.
Step
Set the target setpoint (degrees centigrade)
10.
Dwell
Choose time to dwell at setpoint.
Specify Auto-Hold type: None, Above
setpoint, Below setpoint, Band