FUNCTION 28: CR AT MPP + 1
This function implements an IBM RPQ and will have effect as soon as it is received. .
SYNTAX: %Y28,
OPTION DESCRIPTION
*0
1st Print Position (PP) on next line when CR is
registered
at
MPP+1
1
1st PP on current line when CR is registered at
MPP+1
RELATED:
Y29, NL at MPP + 1
NOTES:
1. This function corresponds to the following IBM RPQ options
4214: OPT 15=1.
3268: SC9501
3287: S30219
2. Available only in non-SCS operation.
EXAMPLE: %Y28,1%
will set 1st PP on current line when CR is received at MPP+1
FUNCTION 29: NL AT MPP + 1
This function implements an IBM RPQ and will have effect as soon as it is received.
SYNTAX: %Y29,
OPTION DESCRIPTION
*0
1st Print Position (PP) on current line + 2 lines
when NL is received at MPP+1
1
1st PP on next line when NL is received at MPP+1
RELATED
Y28, CR at MPP + 1
NOTES:
1. This function corresponds to the following IBM RPQ options:
4214: OPT 15=1.
3268: SC9502
3287: S30219
2. Available only in non-SCS operation.
EXAMPLE: %Y29,1%
will set 1st PP on next line.
FUNCTION 30: VALID FF FOLLOWED BY DATA
This function implements and IBM RPQ and will have effect as soon as it is received.
SYNTAX: %Y30,
OPTION DESCRIPTION
30