P/N 115109 - Direct Vent Option Installation Instructions
Installing a Direct Vent Fan (Supplied By Others)
! VERY IMPORTANT !
The direct vent fan must not exhaust into a wall, ceiling, crawl space, or any other concealed space
of a building nor a gas vent or any other common vent.
The direct vent fan must exhaust to the outside of the building.
1. The exhaust vent fan supplied by others
must supply 250 CFM at 1/4" S.P.
suitable for installation as part of the
direct vent option.
2. Duct work, duct reducer associated
fasteners, and connectors must be
supplied by others.
3. The installation of a 6" to 4" duct
reducer is highly recommended as
shown in Figure A at left.
4. The length of duct and the location
of the vent fan must conform to
local codes and regulations.
! ATTENTION !
The vent installation must be performed by qualified
personnel in accordance with all local codes and regulations.
The direct vent option requires an exhaust vent fan capable of supplying 250CFM at 1/4" S.P.
at the dishwasher. Refer to Figure A below for the recommended configuration of the vent
duct at the dishwasher.
Direct Vent Shroud
Duct Reducer
(by others)
Vent Duct
(by others)
To
Vent Fan
(by others)
A