Digital Temperature Display Description
The wash tank and the final rinse temperatures are numerically displayed and a colored bar
around the numbers creates a visual indication of the temperature.
1. When the color of the bar is yellow then the water temperature
is below the minimum temperature required to operate the
machine. Wait until the temperature has reached the proper
operating temperature.
2. When the color of the bar is yellow and green then the water
temperature is at or above the minimum temperature required
to operate the machine.
3. The required wash temperature is a minimum of 150ºF/66ºC.
Wait until the display indicates this temperature before
washing dishes.
4. The required final rinse temperature is a min/max of
180-195ºF/82-91ºC. Contact a factory authorized service
agent if the display fails to indicate this temperature
during the final rinse.
NOTE:
The final rinse display may indicate a temperature that is less than a minimum of 180ºF/82ºC
during the wash cycle. This is normal, but during the final rinse (when the pressure gauge
indicates a flowing pressure of 20-22 PSI), the final rinse temperature display will read between
180-195ºF/82-91ºC.
Y
EL
LO
W
G
RE
EN
Y
EL
LO
W
G
RE
EN
Temperature Display Error Codes
A digital display may show an error code to indicate certain conditions that require service or
repair. Refer to the illustrations below for the meaning of the error codes.
E
H
H H
The letter "E" is displayed with a dark color
bar indicates a problem exists in the electrical
circuit. Contact an authorized service agent
to correct the problem.
Three "H"s displayed with the color bar fully
lit indicates the temperature has exceeded
210ºF/99ºC. Contact an authorized service
agent to correct the problem.