5 serial/ip advanced settings – Atop Technology SE5001 Series User Manual
Page 62
User Manual Version 1.6
SE5001 Serial Device Server
Copyright © 2011 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
61
Figure 4.17 Port Monitor Trace Panel
The Trace panel provides a detailed, time-stamped, real-time display of all Serial/IP COM ports
operations (Figure 4.17). Click on Enable Trace to start logging Virtual COM communication. Click on
File->Save As and send the log to Atop for analysis If problems arises with Virtual COM.
4.5 Serial/IP Advanced Settings
In the Serial/IP Control Panel, Click on the Advanced button to open Advanced Settings window (Figure 4.18).
Click on Use Default Settings to load the default settings.
Extend Server Connection
Maintains the TCP connection for specified amount of time after COM port is closed
Attempt Server Connection
Terminates pending connection attempts if they do not succeed in the specified time
Synchronize with Server Upon COM Port Open
Required by NT Systems (2000, XP, Vista, 7)
Update Routing Table Upon COM Port Open
Maintains IP route to a server in a different subnet by modifying the IP routing table
Enable Nagle Algorithm
Provides better network efficiency by imposing a minor latency on the data stream while it waits to fill network
packets
Always Limit Data Rate to COM Port Baud Rate
Limits the data rate to the baud rate that is in effect for the virtual COM port