Software setup, 1 configuration by serialmanager, Static ip – Atop Technology SE5001 Series User Manual
Page 14
User Manual Version 1.6
SE5001 Serial Device Server
Copyright © 2011 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
13
3. Software Setup
SE5001 Ethernet Serial device server is shipped with default settings shown in the following table:
Property
Default Value
IP Address
10.0.50.100
Gateway
10.0.0.254
Subnet Mask
255.255.0.0
User Name
admin
Password
Null(leave it blank)
COM 1
9600,None, 8, 1, No flow control, buffer disabled, packet delimiter timer 2ms
Link 1
Type: TCP Server, Listen port 4660, Filter=0.0.0.0, Virtual COM disabled
SysName of SNMP
name
SysLocation of SNMP location
SysContact of SNMP
contact
3.1 Configuration by SerialManager
3.1.1. Static IP
Use SerialManager in the product CD to configure network parameters of SE5001.
->Execute SerialManager (Figure 3.1)
->In SerialManager, click on the SE5001 that needs to be configured.
->Click on
“Configuration”->”Network” or the “Network” button.
->Enter the desired network settings in the
“Network Settings” window (Figure 3.2).
->Click
“OK” and SE5001 will restart and apply new settings.