Configure se5001 as tcp client – Atop Technology SE5001 Series User Manual
Page 21
![background image](/manuals/554954/21/background.png)
User Manual Version 1.6
SE5001 Serial Device Server
Copyright © 2011 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
20
3. If IP filter is enabled, only source IP assigned can connect to SE5001
’s COM.
4. If the multi-connection firmware is installed, SE5001 will prompt for
“Multi_Port”, meaning multiple
connection
3.2.6. Configure SE5001 as TCP Client
Figure 3.11 Link Mode: TCP Client Setup
Type 2
in the “Input choice(1~5) and enter:“
Input destination IP in the “Please input Destination IP:”
Input destination port in the “Please input Destination port:”
Select TCP connection behavior: 1 for connect always, 2 for connect on serial data
If 2 is selected, console will prompt for additional configurations.
Input idle time to disconnect in the “Please input idle time to disconnect(0sec , 1~255):” (Input 0 to
disable; Input 2 to disconnect TCP connection after 2 seconds of serial Inactivity)
Input error retrying
time in “Please input waiting time for error retrying(0 minute,1~255):” (Input 0 to
disable; Input 2 to try to connect to a TCP Server every 2 minutes)
Input idle time in “Please input idle time to send TCP alive packet(x*10sec):”(Input 2 to the send TCP
keep alive packet every 20 seconds)