Configure se5001 as tcp server – Atop Technology SE5001 Series User Manual
Page 20
User Manual Version 1.6
SE5001 Serial Device Server
Copyright © 2011 Atop Technologies, Inc.
All rights reserved. Designed in Taiwan.
19
3.2.5. Configure SE5001 as TCP server
Figure 3.10 Link Mode: TCP Server Setup
Type 1 (Link Mode)
from “Input choice and enter (1~4):” of COM1
Type 1 (TCP Server)
in the “Input choice(1~5) and enter:”
Input local port in the “Please input local port:”
To Enable IP filter:
Input y
in the “Do one want to enable IP filter(y/n)?” to enable IP Filter. Otherwise input n.
Input source IP in the “Please input Filter_IP :”
Double click “Enter” key
Input idle time in “Please input idle time to send TCP alive packet(x*10sec):”(ex. Input 2 to change the
sending TCP keep alive packet period to 20 sec)
Note:
1.
IP filtering function is disabled if setting FILTER_IP to “0.0.0.0”.
2. IP filter is disabled by default