beautypg.com

Telephone interface fxo (for pbx extension line), Dial thru parameters, Sms sending input – 2N Analogue UMTS gateway 2N SmartGate UMTS - Manual, 1699 v1.1.0 User Manual

Page 73: Data interface, Technical parameters 5.1

background image

Technical Parameters

5.1

73

Telephone Interface FXO (for PBX extension line)

Interface type

2-wire analog, FXO

Telephone connector type

RJ 12, 6/2

Line impedance

Zr (TBR21) or 600 W (According to model of Gateway)

On-hook DC resistance

1 MW

Off-hook line current

10 - 65 mA

Off-hook line voltage (typ.)

4,5 V for 25 mA

Dial tone frequency

adjustable, default 425 Hz

Dialing type

tone (DTMF)

Ringing voltage

Min. 20 Vrms 25-50 Hz

Ringing impedance

4 - 10 kW / 50 Hz

Dial thru parameters

Voltage drop (typ.)

1,7V / 25 mA

Closed loop resistance (typ.) 6 W

SMS Sending Input

Closed loop resistance

max. 1 kW

Open loop resistance

Min. 25 kW

Input overvoltage protection

max. +/- 12 V

Data Interface

Interface type

USB 2.0

Connector

USB type B