Table of parameters 3.2 – 2N Analogue UMTS gateway 2N SmartGate UMTS - Manual, 1699 v1.1.0 User Manual
Page 46

Table of Parameters
3.2
46
Setting options:
0-16 characters (0-9,*,#,+)
Default setting:
blank
Substring
Function No.: -
Parameter is used to make filling CLI prefix easier. If parameter "Substring" > 0,
2N® SmartGate UMTS searches filled prefix as substring of the received CLI, but
max. to position given by "Substring" parameter. Positions are counted from
zero.
for example received CLI +420603198222 corresponds with settings:
CLI - calling number
Substring
+420603198222
any setting
+420603
any setting
+420
any setting
603198222
4, or more
603
4, or more
Setting options:
0-15
Step:
1
Default setting:
0
Route to
Function No.: 591
It is possible to route incoming UMTS/GSM call to FXS or FXO interface, or reject
it. When the call is routed to FXS port you can use the CallBack feature. For
correct functionality please set up "Max. ring time for Callback" parameter.
Setting options:
FXS -incoming call is routed to FXS
FXO -incoming call is routed to FXO
FXS CallBack -incoming call is routed to FXS with
CallBack functionality
reject -incoming call is rejected
Default setting:
FXS
Dial in
Function No.: 592
Parameter "Dial in" is used for automatic connection to switchboard operator, or
directly to other subscriber. If this parameter is blank, calling person has
telephone line fully at disposal and has to dial the subscriber number by DTMF.
You can fill only # character to disable Integra function.
Setting options:
0-16 characters (0-9,*,#)
Default setting:
blank
Time limit [min]
Function No.: 599
After time elapsing is call connection terminated immediately. You can hear beep
30s before end of call. 10s before end you can hear beep every second. The "0"
setting means that the function is disabled.
Setting options:
0-255 min
Setting step:
1 min
Default setting: