Table of parameters 3.2 – 2N Analogue UMTS gateway 2N SmartGate UMTS - Manual, 1699 v1.1.0 User Manual
Page 42

Table of Parameters
3.2
42
n
Accelerate connection establishing by allowing to terminate dialing with a #;
n
Modify the number to be dialed by removing and/or adding prefix.
The principle of table function is the same as in the FXS routing table. The call is
controlled according to parameters on the row with dialed number prefix match.
Remember to fill in the "Other prefixes" line for a number whose prefix is not found in
the table.
FXO calls route to
Function No.: 400
The main parameter for FXO calls routing. You can program 2N® SmartGate
UMTS as DialThru gateway, or as gateway for extension line of PBX.
DialThru gateway: Incoming ringing is immediately connected to FXS
interface. If function ME set, 2N® SmartGate UMTS starts to establish
UMTS/GSM call to ME number after defined number of rings. Routing table FXO
is not active.
Gateway for extension line of PBX: 2N® SmartGate UMTS detects incoming
ringing and Off-Hook the line after programmed number of rings, if it is possible
to make call to UMTS/GSM. 2N® SmartGate UMTS generate dial tone and after
dialing takes an action according to FXO routing table.
Setting options:
FXS - DialThru gateway (0)
GSM - gateway for extension line of PBX (1)
Default setting:
FXS - DialThru gateway
ME number
Function No.: 401
If you program 2N® SmartGate UMTS as DialThru gateway, fill in telephone
number for ME function. 2N® SmartGate UMTS starts to establish UMTS/GSM
call to ME number after defined number of rings. Then you can receive incoming
FXO call on telephone line or in UMTS/GSM network. Blank parameter disables
ME function.
Setting options:
0-16 characters (0-9,*,#,+)
Default setting:
blank
Number of rings to ME
Function No.: 402
If you program 2N® SmartGate UMTS as DialThru gateway and ME number is
filled in, 2N® SmartGate UMTS starts to establish UMTS/GSM call to ME number
after defined number of rings. Then you can receive incoming FXO call on
telephone line or in UMTS/GSM network.
Setting options:
0-255
Step:
1
Default setting:
1
Password for ME activation / disabling
Function No.: 403
If you program 2N® SmartGate UMTS as DialThru gateway and fill in ME
number, function ME is active. If you fill in password for ME activation/disabling,
you can activate/disable function ME without PC programming.
Off-Hook FXS line and dial PASSWORD plus
to disable the function.