2 table of parameters, Telephone interface fxs parameters, Table of parameters 3.2 – 2N Analogue UMTS gateway 2N SmartGate UMTS - Manual, 1699 v1.1.0 User Manual
Page 30: Dialing parameters

Table of Parameters
3.2
30
3.2 Table of Parameters
All programmable parameters are listed in this section. Each parameter is
accompanied with the unit used, function number (if avaliable) for programming via
a telephone line, description of SmartGate UMTS's behavior, setting options, setting
step and default (initialization) value.
Numeric parameters must be set in unit listed in the parameter description. For
parameters with different setting are values defined in the parameters description
(for phone line programming in parenthesis). When phone line programming is
used, character
can’t be included in the string, because it is dedicated for
confirmation of the new parameter value.
Telephone interface FXS parameters
Dialing parameters
Type of dialing
Function No.: 100
Select the dialing type to be received by 2N® SmartGate UMTS on the FXS
interface. 2N® SmartGate UMTS accepts only the selected type of dialing,
ignoring the others.
Setting options:
DTMF (0) -2N® SmartGate UMTS receives tone dialing
only.
Pulse (1) -2N® SmartGate UMTS receives pulse
dialing only
Default setting:
DTMF
Time to dial [s]
Function No.: 101
Timeout during which 2N® SmartGate UMTS waits for further digits to be dialed.
It starts to establish connection when this timeout passes.
Setting options:
1-255 s
Setting step:
1 s
Default setting:
5 s
Minimal On Hook [ms]
Function No.: 102
The minimum line current break that 2N® SmartGate UMTS evaluates as hang-
up.
Setting options:
100-25500 ms
Setting step:
100 ms
Default setting:
500 ms
Beep after dialing end
Function No.: 103
Select a beep to signal the end of dialing (beginning of outgoing call
establishing).