Table of parameters 3.2 – 2N Analogue UMTS gateway 2N SmartGate UMTS - Manual, 1699 v1.1.0 User Manual
Page 43

Table of Parameters
3.2
43
Off-Hook FXS line and dial PASSWORD plus
to activate the function again.
Setting options:
0-8 characters (0-9)
Default setting:
blank
Operator for Integra
Function No.: 405
In some UMTS/GSM networks you can add to dialed number # character and
PBX subscriber number. Subscriber number is displayed on other side together
with CLI. This parameter take place when dialed number doesn't contain #
character. Common parameter for both FXO and FXS port.
Setting options:
0-8 characters (0-9)
Default setting:
blank
DTMF code for On-Hook
Function No.: 409
Using this code, you can terminate call to UMTS/GSM network, if busy tone
detection on 2N® SmartGate UMTS fails, or if connected equipment doesn't
transmit busy tone.
Setting options:
0-8 characters (0-9,*,#)
Default setting:
blank
Caution
n
Configuration using phone line programming (DTMF) is applicable for line
‘Other prefixes’ only.
Prefix
Function No.: -
Dialed number prefix identifying the call type. "Other numbers" line is used for
calls with prefixes that are not included in the table.
Setting options:
0-16 characters (0-9,*,#)
Default setting:
blank
Call enable
Function No.: 491
This parameter allows/bars calls with corresponding prefixes.
Setting options:
YES(1)/NO(0)
Default setting:
YES
Number length
Function No.: 493
The parameter defines the expected length of dialed number. It enables to start
dialing into UMTS/GSM or FXO interface immediately after the last digit is dialed.
If the telephone number to be dialed is shorter, a timeout is respected. The "0"
setting means that the function is disabled.
Setting options:
0, 3-15
Setting step:
1
Default setting:
0