SECTION 5 - CONTROL COMPONENTS
5-24
– JLG Lift –
3121222
5.10 BATTERY CHARGER/INVERTER (OPTION)
- INSTALLATION
The battery charger-AC-inverter is located in the compart-
ment at the rear of the machine, remove the charger/step-
plate cover to gain access to the charger.
For further specification and troubleshooting information
refer to the manufacturers’ Charger/Inverter Owner’s
Guide shipped with the machine. Publication - RM1024-
JLG - Part # 3128406.
Also see Section 8 - Figure 9-20., Battery Charger/Inverter
Electrical Connection Schematic for more detailed con-
nection information.
Battery Charger/Inverter Assembly - Installation
1. Charger/Inverter Assembly
2. Insulate Mounting Pad
3. Attach Screws (a)
4. Nylon Shoulder Washers
Note: (a) On final assembly apply Loctite #242 to screw threads
LED/Power/Interlock Cable - Identification
1. AC Output Connector
2. AC Input Connector
3. Remote On/Off Switch Cable
4. External DC Fuse Location
5. DC (–) Connection
6. DC (+) Connection
BATTERY CHARGER/AC INVERTER
SPECIFICATION
AC INVERTER - SPECS
Output Power (Continuous)
1000 W
Output Power (Surge)
3000 W
AC Output Current
36 A
AC Output Voltage
115 to 125 VAC
Output Frequency
60 Hz
DC Input Voltage
21.2 to 29 VDC
Remote ON/OFF
Yes
CHARGER - SPECS
Nominal DC Output Voltage
28 VDC
Maximum DC Output Voltage
33 VDC
Maximum DC Output Current
23 to 27 ADC
Required Interlock Current
1 A
Input Voltage (AC)
100 to 130 VAC
Nominal Input Voltage (AC)
120 VAC
Input Frequency
54 to 66 Hz
OPERATION
Charging Indicator
Yellow LED
100% Charge Indicator
Green LED
Fault Indicator
Red LED
PROTECTION
Output Reverse DC Polarity
125 A Replaceable Fuse
Output AC Short Circuit
Electronic Protection -
Automatic Reset
AC Overload
20 A Internal Slow Blow
Charger Fuse
DC Overload
Voltage Limited - Internally
Controlled
MECHANICAL
Operating Temperature
–40°F to +185°F
(–40°C to +85°C)
Housing
Shock and Water Resistant
Aluminum