Table 6-13. Load Moment Pin Troubleshooting: Moment Pin Sensor Fault
STEP
FAULT CODE/SYMPTOM
REPAIR
YES
NO
1
8/6 MOMENT PIN SENSOR FAULT The moment
pin has reported a fault flag
Use the Analyzer, scroll to the
DIAGNOSTICS menu, press
ENTER, then scroll to the
MOMENT menu, and press
ENTER, check to see if PIN E
FLAGS has any numbers on the
screen display.
Replace load moment pin
& Perform the Boom Sen-
sor calibration process
Contact JLG Service
Dept.
Table 6-14. Load Moment Pin Troubleshooting: New Moment Pin Detected Fault
STEP
FAULT CODE/SYMPTOM
REPAIR
YES
NO
1
8/6 NEW MOMENT PIN DETECTED FAULT A
moment pin was detected on the system different
from the one used to calibrate the machine.
Perform the Boom Sensor cali-
bration process to accept the
new load moment pin.
Verify BCS check and
review all faults prior to
contacting JLG Service
Dept.
Contact JLG Service
Dept.