JLG 1100S Service Manual User Manual
Page 310
SECTION 6 - JLG CONTROL SYSTEM
6-36
– JLG Lift –
3121256
BOOM:
U LIFT
UP/DOWN XXX%
Displays main lift joystick direction & demand
SWING
RIGHT/LEFT XXX%
Displays swing joystick direction & demand
QPRX1
ACTIVE/NOT ACTIVE
Displays status of Q-Prox sensor in lift/swing joystick (Displayed if
JOYSTICK TYPE = 1)
QPRX2
ACTIVE/NOT ACTIVE
Displays status of Q-Prox sensor in lift/swing joystick (Displayed if
JOYSTICK TYPE = 1)
LEVEL
UP/DOWN XXX%
Displays basket level switch direction & demand. NOTE: demand
is controlled by the pump pot
ROT.
RIGHT/LEFT XXX%
Displays basket rotate switch direction & demand. NOTE:
demand is controlled by the pump pot
U TELE
IN/OUT XXX%
Displays main telescope switch direction & demand. NOTE:
demand is controlled by the pump pot
T TELE
IN/OUT XXX%
Displays tower telescope switch direction & demand. NOTE:
demand is controlled by the pump pot
Not displayed if TOWER TELE=NO (machine digit = 0)
T LIFT
UP/DOWN XXX%
Displays tower lift switch direction & demand. NOTE: demand is
controlled by the pump pot
Not displayed if TOWER LIFT=NO (machine digit = 0)
JIB
UP/DOWN XXX%
Displays jib lift switch direction & demand. NOTE: demand is con-
trolled by the pump pot
Not displayed if JIB = NO (machine digit = 0)
JIB
RIGHT/LEFT XXX%
Displays jib swing switch direction & demand. NOTE: demand is
controlled by the pump pot
Displayed if JIB = SIDESWING (machine digit = 2)
JIB INLINE
OP/CL
Displays status of jib inline limit switch. Displayed on models
equipped with the Jib Stow System
JIB LIMIT
OP/CL
Displays status of jib right limit switch. Displayed on models
equipped with the Jib Stow System
JIB LIM OVRD
OP/CL
Displays status of jib limit override switch. Displayed on models
equipped with the Jib Stow System
PCV
ON/OFF
Displays status of Platform Control Valve. Displayed on models
equipped with Electronic Platform Leveling.
PUMP POT
XXX%
Displays pump pot demand. Not displayed if MODEL = 601
(machine digit = 4)
CREEP
ACTIVE/NOT ACTIVE
Displays pump pot creep switch status
CRP MODE
ACTIVE/NOT ACT
Displays creep mode status
Table 6-5. Machine Diagnostics Parameters
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter (Displayed
on Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)
Description