JLG 1100S Service Manual User Manual
Page 307
SECTION 6 - JLG CONTROL SYSTEM
3121256
– JLG Lift –
6-33
TESTING VALVES
Indicates that the valve test is beginning. Each valve is alternately energized and
de-energized; checks are made for open- and short- circuit valve coils.
NOTE: In platform mode, the footswitch must be closed.
NOTE: Tower lift valves are not tested if TOWER LIFT=NO. Tower telescope
valves are not tested if TOWER TELE=NO. Jib valves are not tested if JIB = NO.
Extendable axle valves are not tested if EXT AXLES=NO. Four wheel steer valves
are not tested if 4WS=NO.
NOTE: Left/right jib valves are not tested unless JIB = SIDESWING.
Problems that can be reported include below messages.
CANT TEST VALVES
There is a wiring problem, which prevents the valve test from functioning correctly.
Check valve wiring. Check ground alarm & hour meter wiring.
XXXXXXX S/C
The named valve is drawing too much current so is presumed to be short-cir-
cuited. Check valve wiring.
XXXXXXX O/C
The named valve is drawing too little current so is presumed to be open-circuit.
Check valve wiring.
CHECKING INPUTS
Indicates that the inputs test is beginning. Every input is checked to ensure that it is
in its “normal” position; function switches should be open, cutout switches should
be closed, joysticks should be in neutral.
In platform mode any non-neutral platform switch or joystick is reported; any
active cutouts are reported.
In ground mode any non-neutral ground switches is reported; any active cutouts
are reported.
NOTE: Switches, which are not in use (due to the settings of machine digits), are
not checked.
NOTE: The pump pot is checked only for a wire-off condition; it can be at any
demand from creep to maximum.
Problems that can be reported include below messages.
CHECK XXXXXXX
The named switch is not in its “normal” position. Check switch & wiring.
CHECK XXXXXXX JOY
The named joystick appears to be faulty. Check joystick.
TESTING LAMPS
Indicates that the lamps test is beginning. Each lamp is energized in turn; a prompt
asks for confirmation that the lamp is lit.
ENTER must be pressed or clicked to continue the test.
NOTE: Lamps, which are not in use (due to the settings of machine digits), are not
checked.
NOTE: Platform Lamps are only tested in platform mode.
NOTE: The GM overload lamp and 500# capacity lamp are not tested.
NOTE: Head and tail lamps are tested in both platform and ground mode if
enabled by a machine digit.
TESTING ALARMS
Indicates that the alarms test is beginning. Each alarm is energized in turn; a
prompt asks for confirmation that the alarm is sounding.
ENTER must be pressed or clicked to continue the test.
NOTE: The platform alarm and the horn are only tested in platform mode.
NOTE: The ground alarm is not tested if GROUND ALARM = NO.
Table 6-4. System Test Messages
Message Displayed on
Analyzer
Message Displayed on
Analyzer
Description