SECTION 6 - JLG CONTROL SYSTEM
3121256
– JLG Lift –
6-23
MAIN TELE-
SCOPE:
ACCEL X.Xs
Displays/adjusts main telescope accel-
eration
0.1 to 5.0 sec
1.5
1.5
DECEL X.Xs
Displays/adjusts main telescope decel-
eration
0.1 to 3.0 sec
0.5
0.5
MIN IN XX%
Displays/adjusts minimum main tele-
scope in speed. Same as Creep speed
0 to 65%
15
15
MAX IN XXX%
Displays/adjusts maximum main tele-
scope in speed
0 to 100%
65
65
58-68
65-75
MIN OUT XX%
Displays/adjusts minimum main tele-
scope out speed. Same as Creep speed
0 to 65%
15
15
MAX OUT XXX%
Displays/adjusts maximum main tele-
scope out speed
0 to 100%
60
60
45-55
50-60
BASKET LEVEL:
ACCEL X.Xs
Displays/adjusts basket level accelera-
tion
0.1 to 5.0 sec
1.5
1.5
DECEL X.Xs
Displays/adjusts basket level decelera-
tion
0.1 to 3.0 sec
0.5
0.5
MIN UP XX%
Displays/adjusts minimum basket level
up speed. Same as Creep speed
0 to 65%
47
47
MAX UP XXX%
Displays/adjusts maximum basket level
up speed
0 to 100%
70
70
MIN DOWN XX%
Displays/adjusts minimum basket level
down speed. Same as Creep speed
0 to 65%
45
45
MAX DOWN XXX%
Displays/adjusts maximum basket level
down speed
0 to 100%
70
70
BASKET ROTATE: ACCEL X.Xs
Displays/adjusts basket rotate acceler-
ation
0.1 to 5.0 sec
1.0
1.0
DECEL X.Xs
Displays/adjusts basket rotate deceler-
ation
0.1 to 3.0 sec
0.5
0.5
MIN LEFT XX%
Displays/adjusts minimum basket
rotate left speed. Same as Creep speed
0 to 100%
60
60
MAX LEFT XXX%
Displays/adjusts maximum basket
rotate left speed
0 to 100%
60
60
24-30
(180)
24-30
(180)
MIN RIGHT XX%
Displays/adjusts minimum basket
rotate right speed. Same as Creep
speed
0 to 100%
60
60
MAX RIGHT XXX%
Displays/adjusts maximum basket
rotate right speed
0 to 100%
60
60
24-30
(180)
24-30
(180)
Table 6-3. Personality Ranges/Defaults
SUBMENU
(DISPLAYED ON
ANALYZER 1ST
LINE)
PARAMETER
(DISPLAYED ON ANALYZER
2
ND
LINE)
DESCRIPTION
RANGE
DEFAULT VALUES
TIME RANGE (SEC)
(SEE SECTION 6.10
FOR MACHINE
ORIENTATION WHEN
SETTING SPEEDS)
1100S
1100SJP
1100S
11100SJP