8. Suction Strainers (In Tank)
Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation.
Remove and clean at time of hydraulic oil
change.
9. Oil Change w/Filter - Deutz
Lube Point(s) - Fill Cap/Spin-on Element
Capacity -
5 Quarts (4.5 L) Cooling System
11 Quarts (10.5 L) Engine w/Filter
16 Quarts (15 L) Total Capacity
Lube - EO
Interval - Check level daily; change every 500 hours
or six months, whichever comes first. Adjust final
oil level by mark on dipstick. Refer to Figure 1-2.,
Deutz Engine Dipstick.
10. Fuel Filter - Deutz
Lube Point(s) - Replaceable Element
Interval - Every year or 600 hours of operation
MINIMUM LEVEL,