SECTION 6 - JLG CONTROL SYSTEM
6-126
– JLG Lift –
3121256
Table 6-12. Load Moment Pin Troubleshooting: Moment Pin Vertical Force Out of Range
STEP
FAULT CODE/SYMPTOM
REPAIR
YES
NO
1
8/6 MOMENT PIN VERTICAL FORCE OUT OF
RANGE The vertical force is out of allowed range.
Check to see if the platform is
overloaded in the vertical posi-
tion. Check the rated capacity
requirement.
Remove excess weight
Go to step 2
2
Check to see if any additional
accessories have been added to
the platform without proper cali-
bration.
Perform the Boom
Sensor calibration
process.
Go to step 3
3
Perform the BCS daily check
procedure to make sure the
boom sections are stopping
correctly at the witness marks
matching their capacity selec-
tion.
Go to step 4
Perform the Boom Sen-
sor calibration process.
4
Inspect the job the machine is
performing, making sure that
there is no additional force
applied when the boom sections
are in the horizontal position.
Also consider weather condi-
tions (Wind).
Go to step 5
Position machine cor-
rectly.
5
Use the Analyzer, scroll to the
DIAGNOSTICS menu, press
ENTER, then scroll to the
MOMENT menu, and press
ENTER, check to see if Actual /
Over / Under moment values are
registering on the screen dis-
play.
Go to step 6
Replace the load moment
pin. & Perform the Boom
Sensor calibration pro-
cess.
6
If the problem still exists, verify
steps 1-5 again before contact-
ing the JLG Service Dept.
Replace the load moment
pin. & Perform the Boom
Sensor calibration pro-
cess.