JLG 1100S Service Manual User Manual
Page 294
SECTION 6 - JLG CONTROL SYSTEM
6-20
– JLG Lift –
3121256
FUNCTION CUTOUT:
17*
0
1
2
3
NO: No drive cutout.
BOOM CUTOUT: Boom function cutout while driving above elevation.
DRIVE CUTOUT: Drive cutout above elevation.
DRIVE CUT E&T: Drive cutout above elevation and tilted.
0
* Only visible under certain market selections.
* Certain market selections will limit function cutout options or alter default setting.
GROUND ALARM:
18*
0
1
2
3
NO: No ground alarm installed.
DRIVE: Travel alarm sounds when the drive function is active (Option).
DESCENT: Descent alarm sounds when lift down is active (Option).
MOTION: Motion alarm sounds when any function is active (Option).
0
* Certain market selections will alter default setting.
OSCILLATING AXLE:
19
0
1
NO: No oscillating axle system installed.
YES: Oscillating axle system installed.
1
TEMPERATURE:
20*
0
1
CELSIUS: Celsius unit selection.
FAHRENHEIT: Fahrenheit unit selection.
1
* Certain market selections will alter default setting.
LEVELING MODE:
21*
0
1
LEVEL ALL: Platform Leveling during all functions.
LEVEL LIFT: Platform Leveling during lift only.
0
* Only applicable with automatic control.
OSCILLATING AXLE:
22
0
1
NO: No oscillating axle system installed.
YES: Oscillating axle system installed.
1
4150364-17
Table 6-2. Machine Configuration Programming Information
Configuration Digit
Number
Description
Default
Number