JLG 1100S Service Manual User Manual
Page 315
![background image](/manuals/551996/315/background.png)
SECTION 6 - JLG CONTROL SYSTEM
3121256
– JLG Lift –
6-41
MOMENT:
Displayed if MODEL NUMBER = 7 or 8
(LB-IN) ACTUAL
XXXXXXXX
Displays current moment value
(LB-IN)
OVER
XXXXXXXX
Displays current over moment setpoint.
(LB-IN)
UNDER
XXXXXXXX
Displays current under moment setpoint.
CAL PT
UNDER
XXXXXXXX
Displays the under moment value recorded during boom sensor
calibration.
CAL PT
WIT YEL
XXXXXXXX
Displays the yellow witness mark moment value recorded during
boom sensor calibration.
CAL PT
WIT GRN
XXXXXXXX
Displays the green witness mark moment value recorded during
boom sensor calibration.
CYL PIN
RATIO
X.XXX
Displays the current cylinder moment pin ratio of X and Y forces.
PIN
E FLAGS
0xXXXX
Displays the current error flag status of the cylinder moment pin.
SKY WELDER
YES/NO
Displays the status of Sky Welder selected during boom sensor
calibration. (Displayed if MODEL NUMBER = 7 or 8)
SKY CUTTER
YES/NO
Displays the status of Sky Cutter selected during boom sensor
calibration. (Displayed if MODEL NUMBER = 7 or 8)
SKY GLAZIER
YES/NO
Displays the status of Sky Glazier selected during boom sensor
calibration. (Displayed if MODEL NUMBER = 7 or 8)
SKY BRIGHT
YES/NO
Displays the status of Sky Bright selected during boom sensor cal-
ibration. (Displayed if MODEL NUMBER = 7 or 8)
PIPE RACKS
YES/NO
Displays the status of Pipe Racks selected during boom sensor
calibration. (Displayed if MODEL NUMBER = 7 or 8)
CAMERA MOUNT
YES/NO
Displays the status of Camera Mount selected during boom sen-
sor calibration. (Displayed if MODEL NUMBER = 7 or 8)
Table 6-5. Machine Diagnostics Parameters
Diagnostics
Submenu
(Displayed on
Analyzer 1
st
Line)
Parameter (Displayed
on Analyzer 2
nd
Line)
Parameter Value
(Displayed on Analyzer 2
nd
Line)
Description