JLG 1100S Service Manual User Manual
Page 23

SECTION 1 - SPECIFICATIONS
3121256
– JLG Lift –
1-7
4. Wheel Hub
Lube Point(s) - Level/Fill Plug
Capacity - 0.5 quarts (0.5 liters) ± 10%
Lube - EPGL
Interval - Change after first 150 hours then every
1200 hours of operation
Comments - Place Fill port at 12 o’clock position
and Check port at 3 o’clock position. Pour lubri-
cant into fill port until it just starts to flow out of
check port.
5. Hydraulic Return Filter
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300
hours thereafter or as indicated by condition indi-
cator
6. Hydraulic Charge Filter
Lube Point(s) - Replaceable Element
Interval - Change after first 50 hours and every 300
hours thereafter or as indicated by condition indi-
cator.
7. Hydraulic Oil
Lube Point(s) - Fill Cap
Capacity - 55 gallons (208 liters) Tank
Lube - HO
Interval - Check level daily with boom down, axles
retracted, cylinders retracted. Change every 2
years or 1200 hours of operation.
FULL LEVEL (HOT OIL)
FULL LEVEL (COLD OIL)