SECTION 6 - JLG CONTROL SYSTEM
3121256
– JLG Lift –
6-81
2211
22
11
FSW INTERLOCK TRIPPED
The Footswitch was closed
for more then seven sec-
onds.
- Can be reported during
power-up.
2212
22
12
DRIVE LOCKED - JOYSTICK MOVED BEFORE FOOT-
SWITCH
A drive function was
selected with Footswitch
open.
- Can be reported during
power-up.
2213
22
13
STEER LOCKED - SELECTED BEFORE FOOTSWITCH
A steer function was
selected with Footswitch
open.
2215
22
15
D/S JOY. OUT OF RANGE LOW
The D/S Joystick reference
voltage is low.
- Resistive joysticks, these
faults do not occur.
2216
22
16
D/S JOY. OUT OF RANGE HIGH
The D/S Joystick reference
voltage is > 8.1V.
- Resistive joysticks.
- If the reference voltage is >
7.7V then the reference volt-
age is out of tolerance of a
short to battery has
occurred.
2217
22
17
D/S JOY. CENTER TAP BAD
The D/S Joystick center tap
voltage is < 3.08V or >
3.83V.
- Resistive joysticks.
- There is a +/- .1V range.
around these values due to
resistor tolerances
2218
22
18
L/S JOY. OUT OF RANGE LOW
The L/S Joystick reference
voltage is low.
- Resistive joysticks, these
faults do not occur.
2219
22
19
L/S JOY. OUT OF RANGE HIGH
The L/S Joystick reference
voltage is > 8.1V.
- Resistive joysticks.
- If the reference voltage is >
7.7V then the reference volt-
age is out of tolerance of a
short to battery has
occurred.
2220
22
20
L/S JOY. CENTER TAP BAD
The L/S Joystick center tap
voltage is < 3.08V or >
3.83V.
- Resistive joysticks.
- There is a +/- .1V range.
around these values due to
resistor tolerances
2221
22
21
LIFT/SWING LOCKED - JOYSTICK MOVED BEFORE
FOOTSWITCH
A lift / swing function was
selected with Footswitch
open.
2222
22
22
WAITING FOR FSW TO BE OPEN
The Footswitch was closed
during Platform selection.
- Can be reported during
power-up.
2223
22
23
FUNCTION SWITCHES LOCKED - SELECTED BEFORE
ENABLE
A boom function was
selected with Footswitch
open.
2224
22
24
FOOTSWITCH SELECTED BEFORE START
The Footswitch was closed
during engine start.
230
23
0
<<< GROUND CONTROLS >>>
234
23
4
FUNCTION SWITCHES FAULTY - CHECK DIAGNOSTICS/
BOOM
A boom function has both
directions selected
together.
235
23
5
FUNCTION SWITCHES LOCKED - SELECTED BEFORE
AUX POWER
A boom function was
selected before aux power.
Table 6-6. Diagnostic Trouble Code Chart
DTC
Flash
Code
Sequence
Fault Message
Fault Description
Check