7. Pre-operational Inspection
At the start of each work day (or 8 hour shift), an
TL39T qualified operator must perform the Pre-
operational Inspection as listed in the table below.
The purpose of the Pre-operational Inspection is to
keep the TL39T in proper working condition and to
detect signs of malfunction at the earliest possible
time.
The TL39T should be in the STOWED POSITION
and the Master Key Switch set to OFF before you
begin this in spection.
Defective parts and/or equipment malfunctions
jeopardize the safety of the operator and other
personnel, and can cause damage to the machine.
!
DANGER
DO NOT operate an TL39T that is known to be
damaged or malfunctioning.
Repair all equipment damage or
malfunctions, before placing the TL39T into
service.
■
Pre-operational Inspection Table
Item
Service Required
Engine fuel level
Look to see that the fuel tank is full
Fuel tank cap
Check to see that the cap is tight
Engine oil level
Check oil level (between dipstick lines)
Fuel leaks
Visually inspect (hoses and connections)
Engine cooling
Check that grills are not blocked
Wiring harnesses
Visually inspect (installation, condition)
Battery terminals
Visually inspect (no corrosion)
Battery fluid level
Check fluid level (1/4” or 6 mm below filler neck)
Hydraulic oil level
Visually inspect level (between lines on decal)
Hydraulic oil leaks
Visually inspect (hoses, tubes)
Tires and wheels
Visually inspect (condition)
Tire pressure
Check pressure (measure)
Bolts and fasteners
Visually inspect (condition)
Structural damage and welds
Visually inspect (weld cracks, dents)
Lanyard anchor points
Visually inspect (condition)
Platform gravity gate
Check condition and operation
Platform guardrails
Visually inspect (condition)
Flashing light (option)
Visually inspect (operation)
Ground control switches
Actuate and inspect for proper operation
Ground control valve levers
Check operation (causes correct motion)
Ground emergency lower
Check operation (causes correct motion)
Emergency lower
Check operation (causes correct motion)
Platform control box switches
Actuate and inspect for proper operation
Platform emergency lower
Check operation (causes correct motion)
RCD/ELCB AC outlet (option)
Check operation
Platform work lights (option)
Check operation
Placards and decals
Visually inspect (installation, condition)
Platform entry ladder
Visually inspect (condition)