Safety devices – Snorkel TL39T User Manual
Page 23

Rev C
page 2-3
❑
Enable switch (foot) – Optional
Figure 2.8 - Enable Switch (Foot)
The foot switch performs the same function as
the standard enable switch described above.
Stepping on the foot switch is an action that must
be performed, at the same time as another action,
to make the booms/platform move.
Note:
If you have the optional ‘foot switch’ fitted the
Enable switches on the Upper Control Box and the
Ground Control Box will still function.
❑
Bubble level
Figure 2.9 - Bubble Level
A bubble level is located on the trailer side rail,
beside the outrigger controls. Watch the bubble
level while you set the stabilisers. Lower the
stabilisers, one at a time, just enough to center the
bubble in the circle on top of the guage. When the
bubble is centered the platform is level and can be
safely raised.
❑
RCD/ELCB AC outlet (Option)
Figure 2.10 - RCD/ELCB AC Outlet, Vertical
Mounting
The RCD (Residual Current Device) is located at
the base and will protect against short circuits to
earth. When there is a short circuit the RCD will
shut down the 230v AC power to the platform outlet.
To reset the outlet disconnect the power tool lead
from the platform box and reset the RCD at the
base. If the problem persists call a trained service
technician.
❑
Flashing light (Option)
The flashing light alerts people that the booms
/ platform of the TL39T are moving. The light
flashes at about one flash per second any time the
MASTER KEY switch is on. There is no ON/OFF
switch for the flashing light, it cannot be turned off
while the TL39T is running.
Power Input
Connector
At Base
Power Outlet
At Platform
RCD At Base
2. Safety Devices