H - Pump Calibration (Models 22/23 XC)

Recalibration of the pump is necessary if the original gauge has been replaced by another (for any reason) or if
the gauge scale detail (metalcal) is to be replaced. When recalibrating the pump, please leave the
pump/canister fixed in place on the machine.

Tools required:

1 x Allen (hex) key 3/32” A/F

1 x set of Feeler Gauges

>

(1) Using the Allen key provided, wind the
calibration screw up until it is entirely
within the red handle of the pump. Set the
gauge to the first non-zero position (see
the calibration chart or refer to your agent
for details).

(2) Wind the calibration screw down until
the desired clearance is achieved between
the small raised stop pad on the gauge
handle and the pump handle. The correct
clearance can be found on the calibration
chart (refer to your agent for details if
necessary). Measure the distance using
feeler gauges to confirm the clearance
accurately.