beautypg.com

Brocade Communications Systems Brocade MLX Series and Brocade Netlron XMR 53-1002373-02 User Manual

Page 51

background image

Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide

33

53-1002373-02

Router modules

1

For an up to date list of the 10 Gbps XFP-compliant fiber-optic transceivers that are available from
Brocade, refer to the latest version of the Brocade Optics Family Data Sheet, available online in the
following location:

http://www.brocade.com/downloads/documents/data_sheets/product_data_sheets/Optics_DS.p
df

For more information about fiber-optic transceivers and associated cabling, refer to

“Installing a

fiber-optic transceiver”

on page 318.

Power supply requirements for 10Gx4 interface modules

Table 12

lists the power supply requirements for each type of router when installing

BR-MLX-10GX4-X interface modules.

TABLE 12

Power supply requirements for BR-MLX-10GX4-X and BR-MLX-10Gx4-X-ML interface modules

Router type

Number of Gen-2
10GX4-X interface
modules installed

Power supply requirements

MLXe-4

three

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

four

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

MLX-4 and
Brocade NetIron
XMR 4000

four

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

MLXe-8

seven

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

eight

three 1200W PSU
for 3+1 redundancy, install four 1200W PSU

Brocade NetIron
XMR 8000

eight

two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU

All 16-slot routers sixteen

four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU

All 32-slot routers thirty-two

four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU