26

A.

General. Install wiring and ground boiler in accordance

with requirements of authority having jurisdiction, or in

absence of such requirements the National Electrical

Code, ANSI/NFPA 70 and/or CSA C22.1 Electrical

Code.

B.

Wire Vent Damper (if used).

1. Steam or Water with gravity circulation or tankless

heater.
a. Remove one (1) 7/8" knockout from junction

box. Carefully remove transformer - avoid undue

strain on wires.

b. Install Vent Damper Harness into top of junction

box.

c. Remove factory installed jumper plug (if so

equipped) from Vent Damper Receptacle. Plug

Vent Damper Harness into Vent Damper

Receptacle. See Figure 31.

2. Water with intermittent circulation and without

tankless heater.
a. Remove 7/8" knockout and cover from limit

control.

b. Install Vent Damper Harness into top of limit.
c. Remove factory installed jumper plug from Vent

Damper Receptacle. Plug Vent Damper Harness

into Vent Damper Receptacle. See Figure 31.

d. Install cable clamp around flexible Vent Damper

Harness. Attach to jacket top panel. See Figure

33.

3. Note: After vent damper is installed and operated

through one (1) cycle, the control circuit will

operate only when vent damper is in control circuit.

C.

Install thermostat. Locate on inside wall

approximately 4 feet above floor. Do not install on

outside wall, near fireplace, or where influenced by

drafts or restricted air flow, hot or cold pipes, lighting

fixtures, television, or sunlight. Allow free air

movement by avoiding placement of furniture near

thermostat.

VIII. Electrical

Figure 31: Vent Damper Connection Detail

d. Install cable clamp around flexible Vent Damper

Harness. Attach to jacket top panel. See Figure

32.

Figure 32: Vent Damper Harness to Junction Box

DANGER

Positively assure all electrical connections are unpowered before attempting installation or service of

electrical components or connections of the boiler or building. Lock out all electrical boxes with padlock

once power is turned off.

WARNING

Failure to properly wire electrical connections to the boiler may result in serious physical harm.
Electrical power may be from more than one source. Make sure all power is off before attempting any

electrical work.
Each boiler must be protected with a properly fused disconnect.
Never jump out or make inoperative any safety or operating controls.